Common faults and troubleshooting of feeding machine

Common faults and troubleshooting of vacuum feeding machine

Pipeline related faults

Pipeline leakage: Leakage can affect the suction and working efficiency of the vacuum feeder. Check the pipeline connections and seals to ensure there is no air leakage; Tighten the pipeline connection and check the compressed air pressure to ensure it is within the range of 0.4-0.6mpa.

Excessive residual material in the conveying pipeline: The reason may be that the horizontal conveying distance and vertical conveying height are too large, resulting in material residue. The solution is to design a pipeline clearing system for residual materials and regularly clean the residual materials in the pipeline

 

Valve failure

Valve malfunction may result in the inability to transport materials properly. According to the working principle of the feeder, check whether the valve is working properly and replace the worn butterfly valve sealing ring.

 

Malfunctions related to material suction

Unable to absorb materials, blockage of materials, low conveying capacity: reasons include poor material characteristics, easy adhesion, and poor fluidity; Replaced with new materials with significant differences in characteristics; Poor dust removal effect and reduced filtration area. Can increase vibration, sulfurization, stirring and other design to improve material flowability; Adjust systems and pipelines according to different materials; Clean the filter element or cloth bag in a timely manner.

 

There is suction action, but there is no suction or the suction is not smooth: check if there is any air leakage in the exhaust valve on the pulse dust collector; Check if the top cover of the suction bucket is securely closed and if there is any air leakage in the shut-off valve of the negative pressure pipeline; Check if the filter in the pulse dust collector is clogged with dust.

 

Other faults

Powder spraying issue: Check and replace damaged filter elements or cloth bags; Strengthen the sealing of the blowback system and increase the suction valve.

Abnormal shortage of material in the suction bucket of the vacuum feeding machine forming machine: Check if the pipes on the selection station are properly connected.

The suction bucket on the machine is empty, but the touch screen shows missing or full material: check if the photoelectric switch is not aligned or if the screws are not tightened; Check if the aviation plug is plugged in; Check if the sensitivity of the photoelectric switch is normal and if there is any damage.

Once the power is turned on, the fuse will melt: check if there is a short circuit in the solenoid valves of each valve; Check which part of the insurance is burnt out, then check that part of the circuit.

The touch screen displays but cannot start the fan: check if the intermediate relay inside the electrical control box is normal; Check if the power supply has reverse phase; Check if the switches of each suction bucket are turned on and operate them in the settings screen; Check if the fan is overloaded.

Insufficient or abnormal materials in the drying bucket: Check if there are no raw materials in the raw material bucket and add them to the bucket; Check if the micro switch of the micro suction hopper on the drying bucket is functioning properly.

Not capable of automatic suction: Check if the suction time and evacuation time settings are correct; Check if the compressed air source is normal, at 4KG/cm ²; Check if the air shut-off valve, material shut-off valve cylinder, and solenoid valve of the machine are functioning properly.

Unable to power on: Check if the transformer is functioning properly.

 

Common faults and troubleshooting of general feeding machine

Electrical Fault

Power failure or electrical malfunction: Conduct a thorough equipment inspection, update or repair electrical system faults.

Control system failure: If there are problems with PLC, sensors, switches, etc., it is necessary to adjust the control system parameters to ensure stable operation of the equipment. If necessary, contact professional personnel for maintenance.

Motor or driver malfunction: Check the motor and driver, and repair or replace them promptly if there is a malfunction.

 

Unstable operation

Loose or damaged mechanical structure: Check the mechanical structure, tighten loose parts, and replace damaged parts.

Transmission system malfunction: such as loose belts, worn chains, damaged bearings, poor gear meshing, etc., relevant components need to be adjusted or replaced, and lubrication should be maintained.

Inappropriate adjustment parameters of the control system: readjust the adjustment parameters of the control system to ensure stable operation of the equipment.

 

Inaccurate feeding

Sensor malfunction or improper setting: Check if the sensor is working properly, adjust the sensor settings to ensure accurate material detection.

Mechanical guidance device adjustment not in place: Adjust the mechanical guidance device to ensure accurate material positioning.

Mechanical wear or poor lubrication: Replace worn parts, strengthen lubrication, and improve feeding accuracy.

 

Loud noise

Wear or damage of mechanical components: Check and replace worn or damaged mechanical components.

Transmission system failure: deal with transmission system failures, such as replacing damaged bearings, adjusting gear meshing, etc., and adding appropriate lubricants.

Lack of lubrication or lubrication system failure: Check the lubrication system, replenish lubricant or repair the lubrication system.

overheat

Motor or electrical component overload operation: Check the load condition of the motor and electrical components to avoid overload operation. If necessary, perform heat dissipation treatment or replace components with appropriate power.

Cooling system malfunction: Check the cooling fan and other cooling system components, and replace them promptly if damaged.

High ambient temperature and poor heat dissipation: Improve the working environment of the equipment by adding ventilation or cooling devices.

 

Material blockage

If the material feed rate is too fast or the amount of material is too large: adjust the material feed rate and amount to avoid material accumulation.

Sensor malfunction or slow response: Check and repair the sensor to ensure timely detection of material blockage.

Unreasonable mechanical structure design: Evaluate and improve the mechanical structure, optimize the material conveying path.